[Prev][Next][Index][Thread]

Re: More Tuning/Debugging



O
>Date: Tue, 10 Sep 1996 03:20:00 GMT
>From: Richard Quick <richard.quick-at-slug-dot-org>
>To: tesla-at-poodle.pupman-dot-com
>Subject: Re: More Tuning/Debugging
>
>> All,
>
>> Would any one else like to try this measurement? Over volt the
>> 110V tap of your pig and plot the current with the HV open. jim
>
>Yeah, I've seen it too. 
>
>I have a 7200V-240/120 25KVA single bushing pig. After I
>rewired it (HV and LV sides under the oil) for 14,400, two
>bushing operation the idle current went from barely noticeable to
>around 10-12 amps at 240-260 volts.

Richard,

Was this the pig that you posted about rebushing 3 or 4 months ago? If
so, I didn't realize that you had rewound the primary also.

Suggestion for upgrading a 7200V pig to 12+kV?

	Regards,

	jim