[Prev][Next][Index][Thread]

Re: Transformer Question




----- Begin Included Message -----

>From root-at-mediccom.norden1-dot-com Wed Sep 18 08:44 MDT 1996
>Received: from norden1-dot-com (norden1-dot-com [192.153.35.1]) by uucp-1.csn-dot-net (8.7.5/8.7.3) with ESMTP id IAA26195 for <tesla-at-grendel.objinc-dot-com>; Wed, 18 Sep 1996 08:09:37 -0600 (MDT)
X-Authentication-Warning: norden1-dot-com: uumediccom set sender to mediccom!root using -f
To: tesla-at-grendel.objinc-dot-com
From: mark.graalman-at-mediccom.norden1-dot-com (Mark Graalman)
Date: Wed, 18 Sep 1996 04:43:00 -0500
Subject: Re: Transformer Question

 -=> Quoting Tesla-at-pupman-dot-com to All <=-

 Te> Message-ID: <199609160425.WAA05498-at-poodle.pupman-dot-com>
 Te> Newsgroups: tesla.list

 Te> From jparisse-at-ddlabs-dot-comSun Sep 15 21:44:06 1996
 Te> Date: Sun, 15 Sep 1996 13:30:05 -0700
 Te> From: "Jeff W. Parisse" <jparisse-at-ddlabs-dot-com>
 Te> To: tesla-at-pupman-dot-com
 Te> Cc: swan-at-d2-dot-com
 Te> Subject: Transformer Question

 Te> I've been using two 4500VAC 400ma plate transformers pulled from copy 
 Te> machines. These transformers (GE) have an extra winding that is 
 Te> connected to a 660VAC 10uf capacitor.

 Te> Questions: What is the purpose of this capacitor? Power factor 
 Te> correction? Current limiting? What effect would result by changing or 
 Te> removing the capacitor?

 Te> 0---------) || (----------0
 Te> ) || (
 Te> LV In      ) || (
 Te> ) || ( 
 Te> 0---------) || (
 Te> || (
 Te> |--------) || (   HV Out
 Te> |        ) || (
 Te> ---       ) || (
 Te> --- 10uf  ) || (
 Te> |        ) || (
 Te> |--------) || (-----------0

 Te> Thanks...   ...Jeff Parisse

 MG> This is what is called a "Ferroresonant" Transformer, it produces a
 MG> quazi square wave output. Basically, it is a regulated transformer
 MG> the core operates under a saturated condition.


   Mark Graalman

___ Blue Wave/QWK v2.12



----- End Included Message -----