Hi Jim,
Standard practice would be to wire them in parallel, that is to say
primaries to primaries and secondaries to secondaries. This would yield 6k
volts with 90 mA. Careful with the phasing, search the archives for methods.
I thind there is a section on this at the home page of the archives. Correct
me anybody if I am wrong, I am not as savvy as many coilers on this list.
Good luck,
Robert Hanford
----- Original Message -----
From: "Tesla list" <tesla-at-pupman-dot-com>
To: <tesla-at-pupman-dot-com>
Sent: Wednesday, May 12, 2004 5:05 PM
Subject: nst's


 > Original poster: Jimbo07031982-at-aol-dot-com
 >
 > Can anyone tell me how to connect two 6kv nst's together to get 12kv and
 > then a way to put in a 3rd one I have 3 they are all 6kv/30ma and I would
 > like to wire all of them together to get 18kv total out of them thanx.
 >
 >