[Prev][Next][Index][Thread]
Re: Outside testing
- 
To: tesla-at-grendel.objinc-dot-com 
 
- 
Subject: Re: Outside testing 
 
- 
From: "SROYS"  <SROYS-at-radiology.ab.umd.edu> 
 
- 
Date: Tue, 3 Oct 1995 08:49:58 EDT 
 
- 
>Received: from ns-1.csn-dot-net (root-at-ns-1.csn-dot-net [199.117.27.21]) by uucp-1.csn-dot-net (8.6.12/8.6.12) with SMTP id GAA20725 for <tesla-at-grendel.objinc-dot-com>; Tue, 3 Oct 1995 06:51:58 -0600 
 
> All of a sudden a massive bolt broke out from the
> center of the secondary to the primary strike shield.  I turned the 
> power off and refired it.  It is difficult to get it to run without breakouts 
> happening from the coil itself.  I even had the safety gap fire once.
> 
> What is happening here?  Too much power?
I don't know if it's the same thing that I experienced at my much lower 
1kVA level, but I was having the same sort of problem (discharges from 
the middle of the secondary) until I raised my secondary up to loosen 
the coupling.  When I did that, the spark-over stopped and I actually 
gained two inches or so of spark length.
Steven Roys (sroys-at-radiology.ab.umd.edu)