Hi Jason,

RF may be getting back to the variac.  This may be due to the secondary of
the coil not being grounded well enough.

You can attach the variac frame to a small extra ground rod.  That will
drain the voltage too.

It is also possible that your body is close enough to the coil that "you"
are picking up the high voltage RF fields.  Touching the variac is just
like touching the ground.  Only moving further back really helps that.

Cheers,

	Terry


At 05:38 PM 11/22/2001 +0000, you wrote:
>Hi all,
>
>My variac is grounded to the mains ground. On firing up the coil, it becomes
>very live. The ground does work ( I measured continuity between the earth
>socket on the plug and the case) but as soon as I fire up the coil it
>becomes live. Its fine, so long as I only touch the plastic handle...
>
>The coil is grounded to 3x 3' copper ground pipes on a 10m bit of ground
>wire, as is the strike rail, strike rod and neon ground, as well as the
>filter.
>
>Any thoughts???
>
>Best regards,
>Jason
>