[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: surface breakdown was Re: 20 joules at 100 bps vs 4 joules  at  500 bps
- To: tesla@xxxxxxxxxx
 
- Subject: Re: surface breakdown was Re: 20 joules at 100 bps vs 4 joules  at  500 bps
 
- From: "Tesla list" <tesla@xxxxxxxxxx>
 
- Date: Thu, 04 Aug 2005 13:15:17 -0600
 
- Delivered-to: testla@pupman.com
 
- Delivered-to: tesla@pupman.com
 
- Old-return-path: <vardin@twfpowerelectronics.com>
 
- Resent-date: Thu,  4 Aug 2005 13:23:31 -0600 (MDT)
 
- Resent-from: tesla@xxxxxxxxxx
 
- Resent-message-id: <FBq0gC.A.wi.zsm8CB@poodle>
 
- Resent-sender: tesla-request@xxxxxxxxxx
 
Original poster: "Dmitry (father dest)" <dest@xxxxxxxxxxx>
Tl> Original poster: Jim Lux <jimlux@xxxxxxxxxxxxx>
Tl> At 07:25 AM 8/3/2005, you wrote:
>>Original poster: Greg Leyh <lod@xxxxxxxxxxx>
>>
>>Based on experience, 5kV/inch seems to be a reasonable surface
>>gradient to maintain on the outside of a secondary form.
Tl> Is that for creeping discharges on the surface, or a "free air"
Tl> distance from toroid to base?  Seems a bit low for the latter.
"... average field required for breakdown is about 5kv/cm"
isbn 5-89155-013-x
Bazelyan and Raizer "spark discharge", page 18.
it`s for "free air".
-----
I am skeptical about space aliens too, but space aliens have a greater
probability of existence in my opinion than extra garage space...
(c) Richard Quick  6-07-95 03:59