[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Saturable Reactors as Ballast



Original poster: Finn Hammer <f-h@xxxx>



Tesla list wrote:

Original poster: "Mike" <induction@xxxxxxxxxxx>

Hi Carl,

Snip


Next week or two, if I can cut loose from other stuff at work, I will try and use the LRC meter to get you some L values on the AC windings as well as the control windings.
Mike

Mike,

Pls. notice that few LCR meters can supply enough current to produce a usefull measurement on iron cored inductors. By exciting the windings with a typical LCR meter, the iron will be operating in the low "initial permeability" area of the B-H curve, and the readings will turn out to be too small.

Instead, you should connect the windings across a variac, with a Ammeter in series, and calculate inductance according to:
u = wLi

W = Omega = 2*pi*frequency = 2 * 3.14 * 60 = 377

Cheers, Finn Hammer