[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Setting up a pole pig's wiring



Original poster: "Gerry  Reynolds" <gerryreynolds@xxxxxxxxxxxxx>

Hi Bart,

When you say H2 is the side closes to the core, are you saying the inner winding of the H2 coil goes to the bushing. Could you describe the HV winding geometry?? one coil or two??? and how the inner/outer windings are connected??? My nameplate suggest two HV coils, but if this is the case, it would make no sense to me why the inner winding of one of the coils would be brought out to the HV bushing. Everything you have said would make perfect sense if there was only one HV coil.

Gerry R.





Original poster: "Barton B. Anderson" <bartb@xxxxxxxxxxxxxxxx>

You're concern is certainly valid because we got our X's and H's mixed up. H2 should be at RF ground. This is the HV side closest to the core and when looking at the LV bushings, H2 is the HV bushing on the right.