Matt
I'm working on a SS Power Controller now.
YMMV but if the SSR is zero cross fired and
TC noise shifts apparent zero; ZAP.
Plus about 5mA off current w/ SSR turned off. Might work but have a
power contactor as backup wired in series in case SSR fails (usually
shorted which can be really dangerous with HV).
OBTW my controller does have a 90A 600v
contactor upstream of IGBT AC chopper
power cell assembly. Good design and
manufacturing practice...
On Wednesday, October 15, 2014, mddeming--- via Tesla <tesla@xxxxxxxxxx>
wrote:
>
>
>
> Has anyone had experience with using solid state relays in medium-size TC
> Control panels, such as:
>
> Solid State Relay SSR-40DA 40AMP 3-32VDC Output 24-380V AC Solid State
> Module?
>
> Matt D
>
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxx <javascript:;>
> http://www.pupman.com/mailman/listinfo/tesla
>
--
Dave Sharpe, TCBOR/HEAS
Chesterfield, VA USA
Sharpe's Axiom of Murphy's Law
"Physics trumps opinion!"
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxx
http://www.pupman.com/mailman/listinfo/tesla