[Home][2018 Index] Re: [TCML] Pole pigs [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TCML] Pole pigs



Be best to disconnect inside bond and install another terminal bushing to terminate H2. Otherwise you would have a hot housing and need to isolate your mounting.

Sent from my iPhone

> On Dec 9, 2018, at 5:33 PM, Tyler LaVite <tlavite@xxxxxxxxx> wrote:
> 
> Ahh makes sense it’s hard to tell on people’s videos on YouTube no one ever really goes over the exact wiring of them. I’m just use to hooking them up the correct way at work never back feeding them ya know lol just trying to cover everything before I power up for the first time.
> 
> Sent from my iPhone
> 
>> On Dec 9, 2018, at 1:49 PM, Brandon Bebault via Tesla <tesla@xxxxxxxxxx> wrote:
>> 
>> My experience with case grounded equipment was that I needed to lift the grounding for my coil to work. I had these 25kvdc GE capacitors that were case ground or (h2) and when they were on the grass I couldn’t get the coil to work when I built this rack system with the Capacitors lifted on rubber wheels the coil worked. Not absolutely sure if this played a part but I did see small arcs come from the case to the rack on my last performance. 
>> 
>> -Brandon Bebault
>> Santa Rosa, California. 
>> 
>> Sent from my iPhone
>> 
>>> On Dec 9, 2018, at 9:36 AM, Tyler LaVite <tlavite@xxxxxxxxx> wrote:
>>> 
>>> Hello I’d like to start out by saying I am a journeyman IBEW electrician and work closely everyday with a crew of linemen. So I am well aware of safety issues and the dangers of distribution transformers. I have a distribution transformer I’m wanting to wire up and eventually use on my Tesla coil once the weather outside gets better. My question is exactly how to wire it up. It is a single bushing transformer so it has one high leg bushing H1 and the other end of the high side is bonded to the tank so the tank is H2. My plan is to feed it with 240v to both the low side inputs and just leave the neutral leg alone... one question though since the tank is H2 do I need to remove the bonding strap that bonds the tank case to the neutral? Also I plan on ballasting the transformer with a couple large choke transformers I got out of a 30kva battery backup system. 
>>> 
>>> 
>>> Does it sound like I’m on the right track here or am I completely  wrong? I deal with this stuff everyday just not use to running something like this in reverse ya know just want to cover everything before I throw the switch.
>>> 
>>> 
>>> Thank you!
>>> 
>>> Sent from my iPhone
>>> _______________________________________________
>>> Tesla mailing list
>>> Tesla@xxxxxxxxxxxxxxxxxx
>>> https://www.pupman.com/mailman/listinfo/tesla
>> 
>> _______________________________________________
>> Tesla mailing list
>> Tesla@xxxxxxxxxxxxxxxxxx
>> https://www.pupman.com/mailman/listinfo/tesla
> _______________________________________________
> Tesla mailing list
> Tesla@xxxxxxxxxxxxxxxxxx
> https://www.pupman.com/mailman/listinfo/tesla
_______________________________________________
Tesla mailing list
Tesla@xxxxxxxxxxxxxxxxxx
https://www.pupman.com/mailman/listinfo/tesla