Hi Derek, Thanks for your advice! I will be putting a grounded power cord
on the VDG today, and I think it also may be wise to run it through a line
filter I built from a Diagram Bert sent me!
Sent: Saturday, February 17, 2018 4:08 PM
To: Tesla Coil Mailing List
Subject: Re: [TCML] VDG
Doug,
You must move some sort of ground, When a VDG strikes you can get
very large currents flowing especially in the loop of the discharge.
Ideally I would have a separate earth and not depend on the mains
wiring, else you can get spikes into other connected electrical powered
devices.
It is also important that the discharge cannot not make a connection to
the supply, otherwise you may have a long spark backed by mains current.
An earthed box covering the mains powered items is vital to prevent this.
Derek
On 16/02/2018 19:32, doug wrote:
For those also interested in VanDeGraaffs a question
This is a video of a VDG I just finished building, You will notice some
strikes to the dimmer switch, would it be wise to use a 2 wire + ground
for the AC hookup I have instead of the 2 wire only?