[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: CW multiplier (fwd)



Original poster: <sroys@xxxxxxxxxxxxxxxxx>



---------- Forwarded message ----------
Date: Mon, 21 Nov 2005 20:17:53 -0200
From: Antonio Carlos M. de Queiroz <acmdq@xxxxxxxxxx>
To: High Voltage list <hvlist@xxxxxxxxxx>
Cc: hvlist <hvlist@xxxxxxxxxxxxxxxxx>
Subject: Re: CW multiplier (fwd)

High Voltage list wrote:

> From: robert heidlebaugh <rheidlebaugh@xxxxxxxxxxxxxx>
> To: High Voltage list <hvlist@xxxxxxxxxx>
> Subject: Re: CW multiplier
> 
> Gordon: I use 5000v. Very low current. 5 ma. a simple voltage multiplier
> from an old TV set will due quite well,

Just to note that anything above 100 uA (microamperes) is a
=huge= current for a VDG generator operating in plain air.
It's difficult to build one that transports more than 20 uA.
Currents in the few mA range are typical of machines operating
in compressed gas only.

Antonio Carlos M. de Queiroz


-- 
No virus found in this outgoing message.
Checked by AVG Free Edition.