The diodes were a string in series and then inserted into a teflon tube --- 
open on each end for ventilation.  Resistors were 2 watt units at 5 kV.

Dr. Resonance

>
> Dr. Resonance <resonance@xxxxxxxxxx> wrote:
>
> > We charged at 30 kV (AC peak) per stage for output of 600 kV over 20
> > stages. We used Fujitsu diodes (9 kV at 300 mA).
> - No problems when using 9 kV diodes and a 30 kV PSU?
> Could you please specify resistance and power of the resistors as
> well?
>
> > Be sure to use a HV relay to disconnect power supply before firing and
> > also a nice long isolation resistor
> - Thank you for the hint.
>
> Herwig
>
>
> ---------------------------------------
> Greed is the root of all evil!
> ---------------------------------------
>
>
>