Hi Trent,

Good catch! The electrical resistance of Al is 1.6 higher than Cu, so for a
round conductor the multiplication factor would be the square root of that =
1.3. Not that much bigger. If you also take the difference of specific mass
into account (Cu = 3.3 * Al if I'm not mistaken), an aluminium wire will be
twice as light as a copper one with the same electrical resistance!

The differences of the mechanical characteristics however is another
story... (but that's not something for you to worry about)

Greetings from Holland,

Ruud.