[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: rebuilt nst not working



Original poster: "Bill Vanyo by way of Terry Fritz <twftesla-at-qwest-dot-net>" <vanyo-at-echoes-dot-net>

Just curious - if for some reason he couldn't flip one of the
secondaries back to how it should be (like if he plasticoated them in
place), would it be any different if he just hooked the two leads from
the secondaries together, and used that and the NST ground as the supply
lines to his tank circuit?

	- Bill Vanyo

Tesla list wrote:
> 
> Original poster: "Peter Lawrence by way of Terry Fritz
?twftesla-at-qwest-dot-net?" ?Peter.Lawrence-at-Sun-dot-com?
> 
> Sounds like maybe you removed the secondary coils for cleaning and then
> flipped one of them around when sliding them back on the iron core. Now
> flip either one, not both, to return to normal.
> 
> -Peter Lawrence.
> 
> ?
> ?Original poster: "by way of Terry Fritz ?twftesla-at-qwest-dot-net?"
> ?steve.tami.andrews-at-att-dot-net?
> ?
> ?more problems......just put back together a 15000/60
> ?france.the first dry run was ok except for some arcs
> ?{both sides would arc to ground and each other},so i
> ?took it back apart insulated everything..now no arc over
> ?but both sides only arc to ground not each other?what
> ?did i do wrong.used plasticoat to coat both sides of the
> ?sec?i did a 15000/30 the same way it seams to be working
> ?ok..could i have taken too many shims out? any help will
> ?be great, thanks as allways
> ?
> ?