Re: overcoupling



Original poster: "Dr. Resonance" <resonance-at-jvlnet-dot-com> 

Use a 24 x 5 or 24 x 6 inch toroid (twice sec. coilform dia.).  For primary
use a flat spiral.  First pri turn to coilform distance set at 1.25 inches.
First sec. turn should be elevated approx 2.25 inches above the horizontal
plane of the pri coil.

Don't make a fixed pri to start --- use some scrap 12 AWG wire, around 20
turns, tap as necessary, to test prior to final fabrication of pri coil.

Dr. Resonance

Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo   WI   53913