[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: LC III



Original poster: Ed Phillips <evp@xxxxxxxxxxx>

The Medhurst model replaces all those with just one pair of poles or
zeros
(ignoring the zero frequency issue for simplicity)
That pair is selected for accuracy at low frequency and its not the
first
pair of poles or zeros of the full response which is what you measure
when
you measure the fundamental frequency or model it."

	What do you mean here?  This use of poles and zeros puzzles me.

Ed