Vincent,
What is the rating of the fuses you are using? 10 amps?
Are they slow blow or fast blow fuses?
Many old-school name brand variable autotransformers (Variac,
Powerstat) can handle double their rated nameplate current ratings for
short runs of 30 - 60 seconds without being damaged. Can't say the
same for some of the cheap Asian imports, though.
A Variac is not the part of the circuit that provides current
limiting. That is established by the NSTs themselves.
If you want to run 4 NSTs simultaneously, you will need a Variac big
enough to provide the all current they require.
Adding power factor correction capacitors (PFC) to the transformer
input may help manage their current drain.
Dave
On 11/24/2015 7:46 PM, Vincent D'Amore wrote:
Hi All
Recently I've been running my coil controlled by a 10amp variac. I'm
running two parallels 12/30 franceformer neons sign transformers and
have been running this way for several years but as of late I keep
blowing fuses on the variac about every 4th run. I'm not sure if or
what has weakened over time. I would like to run my coil with a much
larger power supply but that obviously won't go over well with my
10amp variac and I certainly don't want to move forward until I know
the weakest point. Any suggestions? Also if I do go with a larger
supply I'm thinking of 4 12/30's in parallel but don't know what to
do for current limiting. Larger variac? Something else? Thanks for
any advice.
Vincent